Mendeleev Safe

MEASUREMENT BASICS / 03

Radiofrequency Electromagnetic Fields

Wi‑Fi, mobile networks and measurement methods

What is measured around wireless devices — and why frequency, location and transmission mode matter.

Wi-Fi router in a bright furnished living room
Explanatory illustration. Not a photograph of a completed survey.
E · V/m
Electric-field strength
S · µW/m²
Power density
Range + time
Basis of a valid measurement

Routers, phones, Bluetooth devices and base stations transmit information using radiofrequency signals. To survey this environment, it is important to know which frequencies the instrument covers, how transmission changes over time and whether the measurement can distinguish sources.

Ceiling Wi‑Fi access point in a home office

Wi‑Fi

Routers and access points at home and in the office.

Mobile-network base-station antennas on a rooftop

Mobile networks

Base stations and phones use different frequency bands.

Bluetooth earphones, a wireless speaker and a smartphone on a table

Bluetooth

Earphones, speakers and other wireless devices.

01 /How radiofrequencies differ from mains-frequency fields

A radiofrequency electromagnetic field has electric and magnetic components. It is not a third independent component in addition to them; it is a different frequency range and a different measurement task.

In the ICNIRP guidelines, the radiofrequency range covers 100 kHz–300 GHz. Home Wi-Fi uses bands around 2.4, 5 and, where permitted, 6 GHz. Mobile networks operate in different bands; the exact set depends on the country, operator and technology. The name “5G” does not identify a single frequency.

The overall radiofrequency-field level

Broadband measurement within the sensor range.

Broadband radiofrequency-field meter on a tripod in a living room
Location, time, instrument range and wireless-device operating mode are recorded. A single number does not separate the contributions of different transmitters.Explanatory illustration. Not a photograph of a completed survey.

02 /What the meter shows

A measurement may be expressed as electric-field strength E in V/m or as power density S in W/m² and its submultiples. These are different quantities. For a plane travelling wave in free space, the relation S = E² / Z₀ is used, where Z₀ ≈ 377 Ω and E is the RMS field strength.

Close to an antenna, near-field conditions may apply and that conversion cannot be used without additional justification. If an instrument displays power calculated from the electric field, this should be considered in the interpretation.

03 /Broadband measurement or spectrum analysis?

A broadband instrument estimates the total received field level within its range. It is useful for an initial survey, finding spatial maxima and comparing identical conditions. One number, however, does not show what share comes from a router and what share comes from an external transmitter.

A frequency-selective measurement separates contributions by frequency. It is useful when a particular band or a complex environment needs to be investigated. But a spectrum analyser alone measures the signal at its input: obtaining field strength in V/m requires a suitable measurement antenna, its antenna factor, cable-loss correction and correct settings.

A peak at a particular frequency helps identify a radio service. To identify a specific device with confidence, direction, transmission mode or the result of a controlled source shutdown must also be checked.

When the signal must be separated by frequency

A frequency-selective method helps investigate individual bands.

Spectrum analyser with a directional measurement antenna indoors
Field measurement requires a suitable antenna, its antenna factor, cable-loss correction and the analyser settings.Explanatory illustration. Not a photograph of a completed survey.

04 /Why range and time are fundamental

An instrument that does not cover a required frequency does not confirm the absence of a signal at that frequency. The report states the sensor range and separately identifies bands that were not checked. A low-frequency wiring meter does not replace an instrument for Wi-Fi and mobile networks.

Wireless devices transmit under changing loads. A router at idle and while transferring data can produce different results. A phone changes mode with connection conditions and the task being performed. The scenario, duration, average and maximum, as well as detector settings, are therefore recorded.

Signals reflect from surfaces in a room. Measurements are made at several points, with a suitable sensor and a method that accounts for its directionality. A single measurement in the centre of a room does not replace a survey of the sleeping or working position.

05 /What the result should contain

A report connects values with place, time, equipment and operating mode. It explains where a total level was measured, where individual bands were separated and which sources were confirmed. A compliance assessment accounts for the applicable standard, frequency and averaging rules.

If the aim is to change the radiofrequency environment, source placement and operating scenarios are checked and measurements are then repeated. Unauthorised radio interference is not part of a survey. Shielding requires verification: degraded mobile reception can change how a phone operates and the power it transmits.

06 /Common question: can a measurement detect a listening device?

An ordinary radiofrequency-field survey assesses the environment but does not establish the purpose of every transmitter. Detecting hidden devices is a separate task with different methods.

Sources and further reading

← Back to EMF measurements

Would you like to understand the radiofrequencyenvironment in your space?

We will discuss the property, your questions and an appropriate measurement scope.

MENDELEEV SAFE

Book a consultation

Tell us what you need. We’ll help you find the next step.

Choose a date and time for your call.

①  Date & time②  Your details

November 2026

All times shown in your selected time zone.

Loading available times…