MEASUREMENT BASICS / 01

Low-Frequency Electric Fields

Where they come from and how they are measured

A clear guide to fields associated with voltage in wiring, outlets and electrical equipment.

Home workspace with a desk lamp, laptop and connected electrical equipment
Illustrative workspace. Not a photograph of a completed survey.
E · V/m
Electric-field strength
50 / 60 Hz
Mains frequency
At the sensor
Location matters

An electric field can exist near an outlet, power cable or desk lamp even when the connected appliance is not operating. To understand the measurements, it is important to distinguish voltage in wiring from the current that powers a device.

01 /Voltage and the electric field

An electric field is associated with electric charges and potential difference. In a home electrical system, its sources include energized conductors: concealed wiring, extension cords, outlets and appliance cables. If a device switch interrupts only part of a circuit, some components may remain energized.

Concealed electrical wiring and a junction box inside a wall

Wiring

Concealed cables in walls and power circuits.

Electrical outlet with a power cable connected

Outlets

Conductors can remain energized.

Switched-off desk lamp connected to an electrical outlet

Lamps

The “off” button does not describe the whole circuit.

In Europe, mains electricity normally operates at 50 Hz; in the United States, at 60 Hz. That means 50 or 60 complete cycles per second. At 50 Hz, one period is 20 milliseconds. The field changes over time with the voltage; it is not the same as a Wi-Fi radio signal.

02 /What a result in V/m means

The measured quantity is electric-field strength, E. Its unit is volts per metre, V/m. A 230 V outlet voltage and a field of 230 V/m are different quantities: the field at a particular location cannot be calculated from mains voltage alone without information about geometry and surroundings.

A sensor measures the field at its location. A reading near an outlet does not describe the whole bedroom. Distance, cable position, metal objects and the operator’s body can all affect the result. The positions of both instrument and operator are therefore part of the method and should be recorded.

03 /How a survey is organised

First, identify places where people spend extended periods: a bed, work chair or child’s desk. Then measure several points at an agreed height and compare conditions: normal equipment operation, a specific device switched off and, where appropriate, an individual electrical circuit switched off.

Measurement at a workstation

The field is checked where a person spends extended periods.

Electric-field meter on an insulating stand beside a workstation
The instrument is placed at the selected point on an insulating support. Sensor position and conditions are recorded.Explanatory illustration. Not a photograph of a completed survey.

To measure an undisturbed field, the instrument is placed on a suitable insulating support and the operator steps away as specified by the instrument instructions. A ground-referenced measurement and a measurement without that reference are different methodological conditions and should not be mixed in one comparison.

A nine-point grid can be used for a bed: three transverse positions at head, torso and foot level. This grid helps show the field distribution, but it is not itself a safety standard.

Surveying a sleeping area

Several positions on the bed are measured and the conditions are recorded.

Bedroom with a bed surveyed at several measurement positions
A sleeping area is surveyed at several points: head, torso and foot level, on the left, in the centre and on the right.Explanatory illustration. Not a photograph of a completed survey.

04 /How to read the findings

A useful report includes a map of measurement points, E values, the instrument frequency range, the signal-processing mode and the measurement conditions. A before-and-after comparison is meaningful only when sensor position and method are the same.

Practical measures are chosen for the source identified: move a cable, increase distance or ask an electrician to inspect the circuit. Measurements are repeated after the change. Electric-field shielding requires competent design and verification; the presence of metal material alone does not prove that a solution is effective.

05 /Common question: does a switched-off lamp mean there is no field?

Not necessarily. It depends on the switch arrangement and which conductors remain energized. The answer comes from comparing measurements, not from the position of the button.

Sources and further reading

← Back to EMF measurements

Would you like to understand the fieldin your space?

Tell us about the property and the questions you want to investigate. We will help define an appropriate measurement scope.

MENDELEEV SAFE

Book a consultation

Tell us what you need. We’ll help you find the next step.

Choose a date and time for your call.

①  Date & time②  Your details

November 2026

All times shown in your selected time zone.

Loading available times…