An electric field can exist near an outlet, power cable or desk lamp even when the connected appliance is not operating. To understand the measurements, it is important to distinguish voltage in wiring from the current that powers a device.
01 /Voltage and the electric field
An electric field is associated with electric charges and potential difference. In a home electrical system, its sources include energized conductors: concealed wiring, extension cords, outlets and appliance cables. If a device switch interrupts only part of a circuit, some components may remain energized.

Wiring
Concealed cables in walls and power circuits.

Outlets
Conductors can remain energized.

Lamps
The “off” button does not describe the whole circuit.
In Europe, mains electricity normally operates at 50 Hz; in the United States, at 60 Hz. That means 50 or 60 complete cycles per second. At 50 Hz, one period is 20 milliseconds. The field changes over time with the voltage; it is not the same as a Wi-Fi radio signal.
02 /What a result in V/m means
The measured quantity is electric-field strength, E. Its unit is volts per metre, V/m. A 230 V outlet voltage and a field of 230 V/m are different quantities: the field at a particular location cannot be calculated from mains voltage alone without information about geometry and surroundings.
A sensor measures the field at its location. A reading near an outlet does not describe the whole bedroom. Distance, cable position, metal objects and the operator’s body can all affect the result. The positions of both instrument and operator are therefore part of the method and should be recorded.
03 /How a survey is organised
First, identify places where people spend extended periods: a bed, work chair or child’s desk. Then measure several points at an agreed height and compare conditions: normal equipment operation, a specific device switched off and, where appropriate, an individual electrical circuit switched off.
Measurement at a workstation
The field is checked where a person spends extended periods.

To measure an undisturbed field, the instrument is placed on a suitable insulating support and the operator steps away as specified by the instrument instructions. A ground-referenced measurement and a measurement without that reference are different methodological conditions and should not be mixed in one comparison.
A nine-point grid can be used for a bed: three transverse positions at head, torso and foot level. This grid helps show the field distribution, but it is not itself a safety standard.
Surveying a sleeping area
Several positions on the bed are measured and the conditions are recorded.

04 /How to read the findings
A useful report includes a map of measurement points, E values, the instrument frequency range, the signal-processing mode and the measurement conditions. A before-and-after comparison is meaningful only when sensor position and method are the same.
Practical measures are chosen for the source identified: move a cable, increase distance or ask an electrician to inspect the circuit. Measurements are repeated after the change. Electric-field shielding requires competent design and verification; the presence of metal material alone does not prove that a solution is effective.
05 /Common question: does a switched-off lamp mean there is no field?
Not necessarily. It depends on the switch arrangement and which conductors remain energized. The answer comes from comparing measurements, not from the position of the button.