An operating appliance, power cable or transmission line can produce an alternating magnetic field. Its level depends on the current flowing and the arrangement of the electrical circuit. A daytime measurement therefore does not always show what happens at night or under peak load.

Cables
The field depends on current and the relative positions of conductors.

Electrical appliances
Motors and cyclical equipment operation.

Electrical installations
Transformers and power circuits near the space.
01 /How a magnetic field arises
Electric current is the movement of charge. A magnetic field forms around a conductor carrying current. Other things being equal, increasing the current strengthens it, but the result inside a building also depends on conductor positions.
In an ordinary cable, current travels to the load along one conductor and returns along another. When the conductors are close together, their fields partly cancel. Separated current paths and an abnormal return path can change the field pattern. High power consumption therefore does not automatically mean a high field throughout a room.
Indoor measurement
We relate the field to source locations and equipment operation.

02 /Which units are used
Indoor surveys normally measure magnetic flux density, B, in nanoteslas or microteslas. American instruments may display milligauss: 1 mG = 100 nT; 10 mG = 1 µT. Before reports are compared, all values should be converted to the same units.
The Earth’s static magnetic field and the alternating field of the electrical supply are different measurement tasks. A mains survey needs an instrument that selects the relevant range of alternating fields. Readings from a phone magnetometer cannot automatically be treated as equivalent to the results of such a survey.
03 /Why measurements are made on three axes
A field has direction. A single-axis sensor can show a lower value when it is rotated relative to the field. A three-axis instrument measures components on mutually perpendicular axes and determines the resultant quantity according to its processing mode.
It is important to distinguish an RMS value, a peak and the maximum over an observation period. They describe different signal properties. Results obtained in different modes cannot be compared directly without explanation.
04 /Why mapping and time logging are needed
A map shows where the field is higher: near a wall, in a room corner or beside a particular device. Time logging shows when it changes. Refrigerators, pumps, heating systems and equipment in a neighbouring space may operate periodically. For power lines and power cables, the load at the time of the survey matters.
If the question concerns a sleeping area, several positions on the bed are measured and, where needed, logging continues overnight. The times when equipment operates are noted with the data. A matching event and field increase helps form a source hypothesis, which is then tested through controlled switching.
Overnight monitoring
One brief measurement does not describe a changing load.

05 /What can be changed
Moving a workstation or source can sometimes reduce the level noticeably. There is no universal “twice as far means four times lower” rule for every household source: the rate of decrease is determined by circuit geometry.
Low-frequency magnetic fields are more difficult to shield than electric fields. Ordinary foil or thin metal mesh is not a universal solution. First identify the source and current paths; the electrical installation should be checked by a qualified professional. The effect of any change is confirmed by a repeat survey.
06 /Common question: if the reading is low now, can the check end?
It depends on the objective. A series of measurements may be enough for a brief check of operating equipment. A variable load or overnight condition requires logging that covers the period of interest.