01 / Start at the head
Points 1, 2 and 3: left, centre and right. Then we repeat the same order at the torso and feet.
METHODOLOGY / SLEEPING AREA
We check the electric field at nine points across the sleeping area in the order described in the NFA1000 manual. We save the results, identify source contributions and verify changes with a repeat measurement.

We place the instrument at each measurement point, record the result and move to the next position.
The colour image illustrates the procedure; it is not a technical drawing or an exact photograph of the NFA1000.HOW WE MEASURE
123456789Points 1, 2 and 3: left, centre and right. Then we repeat the same order at the torso and feet.
At each point, we position the instrument and leave it still until an audible signal confirms the measurement. After the signal, we move to the next point.
Nine separate readings show how the field changes across the sleeping area.
Diagram basis: Gigahertz Solutions NFA1000 manual, version 9.0, § 5.2. The nine-point method is described for alternating electric fields under VDB recommendations. Magnetic fields and radiofrequency signals are assessed separately; this procedure is not a mandatory government standard.
ACCURACY STARTS WITH THE PROCEDURE
We place the instrument on a dedicated non-conductive stand or use an insulating rod. When measuring on the stand, the specialist steps at least 1.5 m away and remains still to reduce the influence of their presence on the readings.
We record instrument settings and equipment operating modes, then compare results at the same points.
We state the points, values, units, measurement conditions and the document used for comparison.
NINE POINTS ARE PART OF THE ASSESSMENT
We check the sleeping area with equipment in its usual operating state. The magnetic field is assessed separately and, where useful, recorded over time.
We switch a lamp, charger or extension lead off one at a time and compare readings. We also investigate nearby wiring and equipment.
We move a source or adjust the bed position, then repeat measurements under comparable conditions.
WHAT THE CLIENT RECEIVES
A map of points, measured levels, identified sources and a before-and-after comparison. Instrument readings are not presented as promises of health improvement.
01Nine-point diagram
02Electric-field values, V/m
03Separate magnetic-field assessment
04Sources and measurement conditions
05Recommendations and repeat check
Tell us about the room and the equipment near the bed, and we will define an appropriate measurement scope.